k8ÓéÀÖ

Transportation

 
 
 
 
 
 

Why ±·´Ç³¾±ð³æ® for transportation?Ìý

From increasing performance and efficiency to reducing lifecycle costs and emissions, ±·´Ç³¾±ð³æ® insulation continues to enable the future of transportation. Whether it’s expanding the options for electric mobility or producing more powerful electrical equipment, the thermal performance and mechanical strength of ±·´Ç³¾±ð³æ® makes it the ideal choice for electrical motor insulation. 

 
 
 
 
 
 
Applications

Why ±·´Ç³¾±ð³æ® for rail?

±·´Ç³¾±ð³æ® insulation makes high-speed rail possible by enabling lighter, compact and more reliable trains. The proven performance of ±·´Ç³¾±ð³æ® can withstand even the most extreme conditions for maximum power capacity. And with its superior durability, ±·´Ç³¾±ð³æ® insulation can help lower operating costs and reduce maintenance over a long-running period of service—for the reliability you and your passengers deserve.

Contact us about ±·´Ç³¾±ð³æ® âžž

 
 
 

Product families




±·´Ç³¾±ð³æ® 300 series
±·´Ç³¾±ð³æ® 400 series
±·´Ç³¾±ð³æ® 800 series
±·´Ç³¾±ð³æ® 900 series

±·´Ç³¾±ð³æ® 300 series for less demanding electrical applications

±·´Ç³¾±ð³æ® 356
Medium-density aramid paper for layer insulation (diamond dotted or not) in liquid-filled transformersÌý

Equipment:
Traction transformer

Ìý

±·´Ç³¾±ð³æ® 400 series – our original benchmark in electrical insulation

±·´Ç³¾±ð³æ® 410
High-density aramid paper widely used in a majority of electrical equipment applications

Equipment:Ìý
Traction motor
Dry-type transformer for power converters

±·´Ç³¾±ð³æ® 416 LAMÌý
Aramid paper for lamination applications in motors, generators and dry-type transformers

Equipment:
Traction motor
Dry-type transformer for power converters

±·´Ç³¾±ð³æ® 464 LAM
Aramid paper for lamination applications in motors, generators and dry-type transformers

Equipment:
Traction motor
Dry-type transformer for power convertersÌý

±·´Ç³¾±ð³æ® 800 series for improved PD and corona resistance electrical applications

±·´Ç³¾±ð³æ® 818
Aramid mica-blended paper for high voltage applications

Equipment:
Traction motor

±·´Ç³¾±ð³æ® 864 LAM
Aramid mica-blended paper for lamination applications in motors, generators and dry-type transformers

Equipment:
Traction motor

±·´Ç³¾±ð³æ® 900 series for liquid-immersed transformers

±·´Ç³¾±ð³æ® 910
Thermally upgraded Kraft cellulose paper with aramid for conductor and layer insulation in liquid-filled transformers

Equipment:
Traction transformer

±·´Ç³¾±ð³æ® 926
High-density aramid paper for conductor insulation in liquid-filled transformersÌýÌý

Equipment:
Traction transformer

±·´Ç³¾±ð³æ® 914
High-density aramid paper for layer insulation (diamond dotted or not) in liquid-filled transformersÌý

Equipment:
Traction transformer

±·´Ç³¾±ð³æ® 993 PSB
Medium-density aramid pressboard for insulation components in liquid-filled transformers

Equipment:
Traction transformer

±·´Ç³¾±ð³æ® 994 PSB
High-density aramid pressboard for insulation components in liquid-filled transformers

Equipment:
Traction transformer

  • ±·´Ç³¾±ð³æ® 300 series +

    ±·´Ç³¾±ð³æ® 300 series for less demanding electrical applications

    ±·´Ç³¾±ð³æ® 356
    Medium-density aramid paper for layer insulation (diamond dotted or not) in liquid-filled transformersÌý

    Equipment:
    Traction transformer

    Ìý

  • ±·´Ç³¾±ð³æ® 400 series +

    ±·´Ç³¾±ð³æ® 400 series – our original benchmark in electrical insulation

    ±·´Ç³¾±ð³æ® 410
    High-density aramid paper widely used in a majority of electrical equipment applications

    Equipment:Ìý
    Traction motor
    Dry-type transformer for power converters

    ±·´Ç³¾±ð³æ® 416 LAMÌý
    Aramid paper for lamination applications in motors, generators and dry-type transformers

    Equipment:
    Traction motor
    Dry-type transformer for power converters

    ±·´Ç³¾±ð³æ® 464 LAM
    Aramid paper for lamination applications in motors, generators and dry-type transformers

    Equipment:
    Traction motor
    Dry-type transformer for power convertersÌý

  • ±·´Ç³¾±ð³æ® 800 series +

    ±·´Ç³¾±ð³æ® 800 series for improved PD and corona resistance electrical applications

    ±·´Ç³¾±ð³æ® 818
    Aramid mica-blended paper for high voltage applications

    Equipment:
    Traction motor

    ±·´Ç³¾±ð³æ® 864 LAM
    Aramid mica-blended paper for lamination applications in motors, generators and dry-type transformers

    Equipment:
    Traction motor

  • ±·´Ç³¾±ð³æ® 900 series +

    ±·´Ç³¾±ð³æ® 900 series for liquid-immersed transformers

    ±·´Ç³¾±ð³æ® 910
    Thermally upgraded Kraft cellulose paper with aramid for conductor and layer insulation in liquid-filled transformers

    Equipment:
    Traction transformer

    ±·´Ç³¾±ð³æ® 926
    High-density aramid paper for conductor insulation in liquid-filled transformersÌýÌý

    Equipment:
    Traction transformer

    ±·´Ç³¾±ð³æ® 914
    High-density aramid paper for layer insulation (diamond dotted or not) in liquid-filled transformersÌý

    Equipment:
    Traction transformer

    ±·´Ç³¾±ð³æ® 993 PSB
    Medium-density aramid pressboard for insulation components in liquid-filled transformers

    Equipment:
    Traction transformer

    ±·´Ç³¾±ð³æ® 994 PSB
    High-density aramid pressboard for insulation components in liquid-filled transformers

    Equipment:
    Traction transformer

 
 
 

Featured resources

 
 
 

Industries we serve

 
 
 
 
 
 
 
 
 

How can we help you?